The system design allows for multiple energy server units to be modularly assembled and anchored. Pre-assembled skids can be transported nationally and internationally and then installed at various customer sites enabling direct-to-user leasing of energy servers and contributes to the client’s sustainability goals. Garrett and the Degenkolb team performed Failure Mode and Effects Analysis (FMEA) and evaluated fragility relative to a range of seismic hazards across the United States for company reliability and quality assurance targets.